Cursor EC
Systemic fungicide for the control of a broad spectrum of pathogens.
Instructions for use
Crops, target organisms and rates. Always follow the label of the product as registered in your country.
| Crop | Target organism | Rate (l/ha) | Application | PHI, days (max. treatments) | Re-entry, days manual (mechanised) |
|---|---|---|---|---|---|
| Apple | Venturia inaequalis (scab) | 0,2 | Foliar spray during the growing season | 20 (2-3) | 7 (3) |
| Rapeseed | Alternaria brassicae (Alternaria leaf spot), Phoma lingam (Phoma / blackleg) | 0,5-0,6 | Foliar spray during the growing season | 68 (1-2) | - (3) |
| Wheat | Erysiphe graminis (powdery mildew), Puccinia recondita (brown rust), Septoria tritici, Septoria nodorum (Septoria leaf blotch) | 0,5-0,6 | Foliar spray during the growing season | 61 (1-2) | - (3) |
| Sunflower | White mould / Sclerotinia rot, Phoma / blackleg, Phomopsis stem canker | 0,5-0,6 | Foliar spray during the growing season | 60 (2) | 7 (3) |
| Plum | Shot-hole disease, red leaf spot | 0,35-0,4 | Foliar spray during the growing season | 30 (2) | 7 (3) |
Technical information
Mode of action
Cursor EC is a systemic triazole fungicide, known for its excellent properties. It acts by inhibiting ergosterol biosynthesis in the cell membranes of pathogenic fungi, which stops their development and growth. Difenoconazole is transported systemically through the xylem vessels and distributed to both surfaces of the plant, providing uniform protection against diseases. It is applied foliarly and has curative and preventive effects.
Physical & chemical properties
Cursor EC is supplied as a yellowish emulsifiable concentrate containing difenoconazole 250 g/l; the product is not corrosive.
Compatibility
Cursor EC is compatible with most pesticides; however, a preliminary compatibility test is recommended for each mixture.
Application technique
Sprayer: use a sprayer that ensures uniform distribution of the spray solution. Application of treatments: use the required spray volume to achieve complete coverage of the plant surface. Fill 1/3 of the sprayer tank with water, then add the required amount of product and, under continuous agitation, top up the tank with the required amount of water. Spray volume: 800–1000 l/ha for fruit crops, 400–600 l/ha for field crops.
Restrictions & limitations
Cursor EC – to be used only on the registered crops and in accordance with the recommended use regulations. Pollution of water bodies with spray solution, as a result of run-off, disposal of leftover solution or washing of equipment, must be prevented.
Phytotoxicity
Cursor EC has no phytotoxic action on agricultural crops when used in accordance with the label recommendations.
Toxicity
Hazard category IV/IV for acute oral toxicity, humans/bees
- Toxicity class (human / bees)
- IV / IV
Safety, storage & disposal
Classification & hazard statements
Signal word: Danger
Hazard statements
- H304 — May be fatal if swallowed and enters airways.
- H315 — Causes skin irritation.
- H319 — Causes serious eye irritation.
- H336 — May cause drowsiness or dizziness.
- H351 — Suspected of causing cancer.
- H410 — Very toxic to aquatic life with long lasting effects.
- EUH401 — To avoid risks to human health and the environment, comply with the instructions for use.
Precautionary statements
- P201 — Obtain special instructions before use.
- P261 — Avoid breathing dust, fume, gas, mist, vapours or spray.
- P273 — Avoid release to the environment.
- P280 — Wear protective gloves, protective clothing, eye protection and face protection.
- P301+P310 — IF SWALLOWED: Immediately call a POISON CENTER or doctor.
- P302+P352 — IF ON SKIN: Wash with plenty of water and soap.
- P305+P351+P338 — IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P308+P313 — IF exposed or concerned: Get medical advice/attention.
- P331 — Do NOT induce vomiting.
- P391 — Collect spillage.
- P501 — Dispose of contents/container in accordance with local regulations.
Safety measures during application
Avoid contact with skin, eyes and clothing. Protective equipment and protective gloves must be worn during work. Use personal protective clothing. Keep work clothing separate. Adequate airing and ventilation of the workplace and storage area is required. Do not eat, drink or smoke when using this product. Hands and/or face must be washed before breaks and at the end of the working day. If medical advice is needed, have the product container or label at hand. Avoid breathing mist, vapours or spray. Do not take contaminated work clothing out of the workplace. After using the product, thoroughly wash the parts of the body that have been contaminated. Take off contaminated clothing and wash it before reuse. Read carefully and follow all instructions.
First aid
In case of eye contact – rinse with plenty of clean water for at least 15 minutes, including under the eyelids. Remove contact lenses if present. In case of skin contact – remove contaminated clothing immediately and wash the contaminated areas of the body with plenty of water. If irritation persists, call a doctor. Wash contaminated clothing before reuse. In case of ingestion – give the victim plenty of water to drink. Do not induce vomiting. Notify a doctor immediately. In case of inhalation – move the victim to fresh air. If breathing is irregular or has stopped, give artificial respiration. Seek medical attention if the victim feels unwell. THERE IS NO ANTIDOTE; TREAT SYMPTOMATICALLY.
Storage & transport
The product shall be stored in its original, sealed packaging, in dry rooms intended exclusively for pesticides, separate from food, beverages, cigarettes and feed. Protect from direct sunlight. Protect from temperatures below 0°C or above +35°C. During handling, transport and storage, occupational safety measures shall be taken and the product shall be protected from extreme temperature variations.
Packaging disposal & decontamination
Avoid any possibility of product leakage, if this can be done safely. Do not discharge the product into surface waters or sewage systems. Contain the spill, then collect the accidentally spilled product by mechanical means and place it in suitable containers for subsequent disposal as hazardous waste. After removing the product, wash the site of the accident with water. If the product contaminates rivers, lakes or drains, inform the competent authorities. After emptying, rinse the containers three times and add the rinsing water to the spray solution. Dispose of empty containers in accordance with the regulations in force. Do not reuse empty containers for any other purpose.
Flammability
The product is not explosive and has no oxidising properties. It is stable under normal storage and handling conditions. Extinguishing media: water spray, alcohol-resistant foam, dry chemical extinguisher or carbon dioxide. Advice for firefighters: use self-contained breathing apparatus and wear full protective equipment if necessary. Thermal decomposition may generate: carbon oxides, nitrogen oxides.